If you are looking for a cost-effective, streamlined and direct way to pass the City & Guilds 18th edition exam, our online training course is designed to give you the tools you will need to pass the exam the first time. The course material has been updated to reflect the latest A2 version of BS7671.
The MJ Electrical Training 18th edition course and exam bundle is only £222.00 Inc VAT. This includes access to our five-star online course material, the City & Guilds final examination, which can be taken from your home, workplace or from one of our centres and when you have successfully passed the final examination the City & Guilds electronic and hard copy certificates.
- Online course material
- Tutor support
- Your emails are answered promptly
- Take the exam within as little as 10 days.
- Home, workplace or centre examinations
- Same day results
- Certification normally within 5 working days
- Electronic and hard copy C&G certificates
Read some of our Reviews here >> Reviews.io >> Trustpilot >>
The final City & Guilds 2382-22 (Amendment 2) examination is sixty questions covering each of the 8 Parts and the Appendices of BS7671. The pass percentage mark is 60% which is 36 questions correct out of 60.
Within this blog post, we have included two sample 20-question past papers, giving you similar questions to the ones you will receive in your final 2382-22 exam.
Enrol today and get automatic access to start the online course material. With our Best Price Promise if you find any like-for-like online course material and examination cheaper anywhere else I will refund you the difference.
The practice test paper can be found below. When you are ready press ‘Start Quiz’ to begin.
0 of 20 Questions completed Questions: You have already completed the quiz before. Hence you can not start it again.
Quiz is loading… You must sign in or sign up to start the quiz. You must first complete the following:
0 of 20 Questions answered correctly
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0) Q4. The regulations do not apply to which of the following installations? Question 4 is a Part 1 question Q5. Illuminance for emergency lighting at the end of the rated operating time is the definition of? Question 5 is a Part 2 question Q11. In the division of an installation. The wiring of each final circuit shall be electrically separate from every other final circuit. Why is this necessary? Question 11 is a Part 3 question Q19. A socket-outlet used for a SELV system must Question 19 is a part 4 question Q21. Where electrical equipment in a single location contains flammable liquid in significant quantity’s. What is generally accepted as the lower limit for a significant quantity? Question 21 is a part 4 question Q23. An automatically controlled motor which is not continuously supervised shall be protected against excessive temperature by which one of the following? Question 23 is a Part 4 question Q24. A non metallic part which does not need to be touched for normal operations has a maximum temperature of ? Question 24 is a Part 4 question Q25. In a AC IT system RA x Id must not exceed? Question 25 is a Part 4 question Q26. A circuit with a 10 mm2 70 (degrees C) thermoplastic copper live conductor has a maximum final temperature of 160 (degrees C). If a short circuit fault current of 600A flows through the conductor, the time taken to reach the final temperature would be? Question 26 is a Part 4 question Q27. Which of the following is NOT an example of a place BS 7671 suggests the use of an AFDD Question 27 is a Part 4 question Q37. What is the minimum allowable size of a copper main protective bonding conductor? Question 37 is a Part 5 question Q38. In a Three-wire DC power circuit, there is a blue wire. What is the function of this conductor? Question 38 is a Part 5 question Q39. A ceiling rose or lamp holder shall not be installed in any circuit operating at a voltage normally exceeding? Question 39 is a Part 5 question Q40. What external influence code letters are used to represent FAUNA? Question 40 is a Part 5 question Q43. What alternative measurement may be used if the value of earth electrode resistance is not practical? Question 43 is a Part 6 question Q44. Which signatures are required on an electrical installation certificate? Question 44 is a Part 6 question Q50. Which of the following is not included within the scope of Section 711 Question 50 is a Part 7 question Q53. What system shall monitor and control the operation of all power supplies within a prosumers electrical installation? Question 53 is a Part 8 question Q58. What parameter is identified by the symbol Ib? Question 58 is an Appendices question Q60. What is the minimum permissible current rating (Iz) of a conductor protected by a 20 A BS 3036 semi-enclosed fuse? Question 60 is an Appendices question
Quiz Summary
Information
Results
Results
0 Essay(s) Pending (Possible Point(s): 0)
Categories
1. Question
Hint
2. Question
Hint
3. Question
Hint
4. Question
Hint
5. Question
Hint
6. Question
Hint
7. Question
Hint
8. Question
Hint
9. Question
Hint
10. Question
Hint
11. Question
Hint
12. Question
Hint
13. Question
Hint
14. Question
Hint
15. Question
Hint
16. Question
Hint
17. Question
Hint
18. Question
Hint
19. Question
Hint
20. Question
Hint
0 of 20 Questions completed Questions: You have already completed the quiz before. Hence you can not start it again.
Quiz is loading… You must sign in or sign up to start the quiz. You must first complete the following:
0 of 20 Questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0) Q1. What is the maximum nominal AC voltage covered by the requirements of BS 7671? Question 2 is a Part 1 question Q4. What is a fundamental principle when considering the type of wiring and method of installation? Question 4 is a Part 1 question Q5. ‘An Earthing of a point or points in a system or in an installation or in equipment for the purposes of safety’ is the definition of? Question 5 is a Part 2 question Q10. Dividing the circuits of an installation is completed in order to achieve? Question 10 is a part 3 question Q11. The following image represents what type of earthing system? Question 11 is a Part 3 question Q22. Where there is a danger of fire due to the nature of stored or processed materials, a 250 W spotlight shall be installed at a minimum distance from combustible materials of? Working through the contents of Part 4 we see Chapter 42 ‘Protection against thermal effects’. Turning to the contents of Chapter 42 we see Section 422 ‘Combustible constructional materials’, working through Section 422, we find Regulation 422.4.2. Q24. What is the maximum tabulated Zs (Ohms) value of a BS3036 5 AMP fuse with a 0.4 s, disconnection time? Question 24 is a Part 4 question Q26. What is the minimum size of copper earthing busbar for an installation which has a supply capacity of 250 A per phase, when considering measures against electromagnetic disturbances? Question 26 is a Part 4 question Q27. Which one of the following is not a form of basic protection? Question 27 is a Part 4 question Q38. Which one of the following devices does not provide? Overload Protection, Short circuit protection and Residual current protection? Question 38 is a Part 5 question Q39. Which of the following may be used as a protective conductor? Question 39 is a Part 5 question Q40. In an electrical installation, a cable is surrounded by 100mm of thermal insulation what would the derating factor be? Question 40 is a Part 5 question Q41. In order to maintain compatibility. Switchgear, protective devices, accessories and other types of equipment shall not be connected to conductors intended to operate at a temperature exceeding? Question 40 is a part 5 question Q44. When an inspector completes insulation resistance tests and reads values equal or greater to Table 64 of BS7671, what might the inspector conclude their results to be? Question 44 is a Part 6 question Q46. What might also need to be considered when installing a socket outlet on a floating walkway at 300mm above the highest point of water? Question 46 is a Part 7 question Q47. Within a Medical location, an Anaesthetic area is considered what group number? Question 47 is a Part 7 question Q48. Which of the following is not included within the scope of Section 711? Question 48 is a Part 7 question Q53. What is an example of a function handled by an EEMS? Question 53 is a Part 8 question Q54. Which test may require alternative methods when verifying a PEI? Question 54 is a Part 8 question Q60. Which of the following is not an item allowed to be recorded on an ‘Minor electrical installation works certificate’? Question 60 is an Appendices question
Quiz Summary
Information
Results
Results
0 Essay(s) Pending (Possible Point(s): 0)
Categories
1. Question
Hint
2. Question
Hint
3. Question
Hint
4. Question
Hint
5. Question
Hint
6. Question
Hint
7. Question
Hint
8. Question
Hint
9. Question
Hint
10. Question
Hint
11. Question
Hint
12. Question
Hint
13. Question
Hint
14. Question
Hint
15. Question
Hint
16. Question
Hint
17. Question
Hint
18. Question
Hint
19. Question
Hint
20. Question
Hint